1.
BMC Infect Dis ; 23(1): 110, 2023 Feb 23.
Article in English | MEDLINE | ID: covidwho-2261264

ABSTRACT

BACKGROUND: Rapid determination of an individual's antibody status can be beneficial in understanding an individual's immune response to SARS-CoV-2 and for initiation of therapies that are only deemed effective in sero-negative individuals. Antibody lateral flow tests (LFTs) have potential to address this need as a rapid, point of care test. METHODS: Here we present a proof-of-concept evaluation of eight LFT brands using sera from 95 vaccinated individuals to determine sensitivity for detecting vaccination generated antibodies. Samples were analysed on eight different brands of antibody LFT and an automated chemiluminescent microparticle immunoassay (CMIA) that identifies anti-spike antibodies which was used as our reference standard. RESULTS: All 95 (100%) participants tested positive for anti-spike antibodies by the chemiluminescent microparticle immunoassay (CMIA) reference standard post-dose two of their SARS-CoV-2 vaccine: BNT162b2 (Pfizer/BioNTech, n = 60), AZD1222 (AstraZeneca, n = 31), mRNA-1273 (Moderna, n = 2) and Undeclared Vaccine Brand (n = 2). Sensitivity increased from dose one to dose two in six out of eight LFTs with three tests achieving 100% sensitivity at dose two in detecting anti-spike antibodies. CONCLUSIONS: These tests are demonstrated to be highly sensitive to detect raised antibody levels in vaccinated individuals. RDTs are low cost and rapid alternatives to ELISA based systems.


Subject(s)
COVID-19 Vaccines , COVID-19 , Humans , BNT162 Vaccine , ChAdOx1 nCoV-19 , COVID-19/diagnosis , COVID-19/prevention & control , SARS-CoV-2 , Antibodies, Viral , Vaccination
2.
Sci Rep ; 12(1): 3351, 2022 03 01.
Article in English | MEDLINE | ID: covidwho-1908222

ABSTRACT

Severe acute respiratory coronavirus 2 (SARS-CoV-2) has spread globally since its emergence in 2019. Most SARS-CoV-2 infections generate immune responses leading to rising levels of immunoglobulins (Ig) M, A and G which can be detected using diagnostic tests including enzyme-linked immunosorbent assays (ELISA). Whilst implying previous SARS-CoV-2 infection, the detection of Ig by ELISA does not guarantee the presence of neutralising antibodies (NAb) that can prevent the virus infecting cells. Plaque reduction neutralisation tests (PRNT) detect NAb, but are not amenable to mass testing as they take several days and require use of SARS-CoV-2 in high biocontainment laboratories. We evaluated the ability of IgG and IgM ELISAs targeting SARS-CoV-2 spike subunit 1 receptor binding domain (S1-RBD), and spike subunit 2 (S2) and nucleocapsid protein (NP), at predicting the presence and magnitude of NAb determined by PRNT. IgG S2 + NP ELISA was 96.8% [95% CI 83.8-99.9] sensitive and 88.9% [95% CI 51.8-99.7] specific at predicting the presence of NAbs (PRNT80 > 1:40). IgG and IgM S1-RBD ELISAs correlated with PRNT titre, with higher ELISA results increasing the likelihood of a robust neutralising response. The IgM S1-RBD assay can be used as a rapid, high throughput test to approximate the magnitude of NAb titre.


Subject(s)
Antibodies, Viral/immunology , COVID-19/immunology , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Neutralization Tests , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Aged , Enzyme-Linked Immunosorbent Assay , Female , Humans , Male , Middle Aged
3.
Sci Rep ; 12(1): 1416, 2022 01 26.
Article in English | MEDLINE | ID: covidwho-1655626

ABSTRACT

The control of the COVID-19 pandemic in the UK has necessitated restrictions on amateur and professional sports due to the perceived infection risk to competitors, via direct person to person transmission, or possibly via the surfaces of sports equipment. The sharing of sports equipment such as tennis balls was therefore banned by some sport's governing bodies. We sought to investigate the potential of sporting equipment as transmission vectors of SARS-CoV-2. Ten different types of sporting equipment, including balls from common sports, were inoculated with 40 µl droplets containing clinically relevant concentrations of live SARS-CoV-2 virus. Materials were then swabbed at time points relevant to sports (1, 5, 15, 30, 90 min). The amount of live SARS-CoV-2 recovered at each time point was enumerated using viral plaque assays, and viral decay and half-life was estimated through fitting linear models to log transformed data from each material. At one minute, SARS-CoV-2 virus was recovered in only seven of the ten types of equipment with the low dose inoculum, one at five minutes and none at 15 min. Retrievable virus dropped significantly for all materials tested using the high dose inoculum with mean recovery of virus falling to 0.74% at 1 min, 0.39% at 15 min and 0.003% at 90 min. Viral recovery, predicted decay, and half-life varied between materials with porous surfaces limiting virus transmission. This study shows that there is an exponential reduction in SARS-CoV-2 recoverable from a range of sports equipment after a short time period, and virus is less transferrable from materials such as a tennis ball, red cricket ball and cricket glove. Given this rapid loss of viral load and the fact that transmission requires a significant inoculum to be transferred from equipment to the mucous membranes of another individual it seems unlikely that sports equipment is a major cause for transmission of SARS-CoV-2. These findings have important policy implications in the context of the pandemic and may promote other infection control measures in sports to reduce the risk of SARS-CoV-2 transmission and urge sports equipment manufacturers to identify surfaces that may or may not be likely to retain transferable virus.


Subject(s)
COVID-19/transmission , SARS-CoV-2/physiology , COVID-19/virology , Half-Life , Humans , Linear Models , SARS-CoV-2/isolation & purification , Sports Equipment , Surface Properties
4.
J Infect ; 84(3): 355-360, 2022 03.
Article in English | MEDLINE | ID: covidwho-1560123

ABSTRACT

BACKGROUND: There are an abundance of commercially available lateral flow assays (LFAs) that detect antibodies to SARS-CoV-2. Whilst these are usually evaluated by the manufacturer, externally performed diagnostic accuracy studies to assess performance are essential. Herein we present an evaluation of 12 LFAs. METHODS: Sera from 100 SARS-CoV-2 reverse-transcriptase polymerase chain reaction (RT-PCR) positive participants were recruited through the FASTER study. A total of 105 pre-pandemic sera from participants with other infections were included as negative samples. RESULTS: At presentation sensitivity against RT-PCR ranged from 37.4 to 79% for IgM/IgG, 30.3-74% for IgG, and 21.2-67% for IgM. Sensitivity for IgM/IgG improved ≥ 21 days post symptom onset for 10/12 tests. Specificity ranged from 74.3 to 99.1% for IgM/IgG, 82.9-100% for IgG, and 75.2-98% for IgM. Compared to the EuroImmun IgG enzyme-linked immunosorbent assay (ELISA), sensitivity and specificity ranged from 44.6 to 95.4% and 85.4-100%, respectively. CONCLUSION: There are many LFAs available with varied sensitivity and specificity. Understanding the diagnostic accuracy of these tests will be vital as we come to rely more on the antibody status of a person moving forward, and as such manufacturer-independent evaluations are crucial.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , Humans , Immunoassay , Immunoglobulin G , Immunoglobulin M , Sensitivity and Specificity
5.
Sci Rep ; 11(1): 7754, 2021 04 08.
Article in English | MEDLINE | ID: covidwho-1174700

ABSTRACT

Serological testing is emerging as a powerful tool to progress our understanding of COVID-19 exposure, transmission and immune response. Large-scale testing is limited by the need for in-person blood collection by staff trained in venepuncture, and the limited sensitivity of lateral flow tests. Capillary blood self-sampling and postage to laboratories for analysis could provide a reliable alternative. Two-hundred and nine matched venous and capillary blood samples were obtained from thirty nine participants and analysed using a COVID-19 IgG ELISA to detect antibodies against SARS-CoV-2. Thirty eight out of thirty nine participants were able to self-collect an adequate sample of capillary blood (≥ 50 µl). Using plasma from venous blood collected in lithium heparin as the reference standard, matched capillary blood samples, collected in lithium heparin-treated tubes and on filter paper as dried blood spots, achieved a Cohen's kappa coefficient of > 0.88 (near-perfect agreement, 95% CI 0.738-1.000). Storage of capillary blood at room temperature for up to 7 days post sampling did not affect concordance. Our results indicate that capillary blood self-sampling is a reliable and feasible alternative to venepuncture for serological assessment in COVID-19.


Subject(s)
Blood Specimen Collection/methods , COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Adult , COVID-19/blood , Dried Blood Spot Testing/methods , Enzyme-Linked Immunosorbent Assay/methods , Female , Humans , Male , Middle Aged , Young Adult
6.
Emerg Infect Dis ; 27(1)2021 01.
Article in English | MEDLINE | ID: covidwho-951873

ABSTRACT

We investigated the dynamics of seroconversion in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. During March 29-May 22, 2020, we collected serum samples and associated clinical data from 177 persons in London, UK, who had SARS-CoV-2 infection. We measured IgG against SARS-CoV-2 and compared antibody levels with patient outcomes, demographic information, and laboratory characteristics. We found that 2.0%-8.5% of persons did not seroconvert 3-6 weeks after infection. Persons who seroconverted were older, were more likely to have concurrent conditions, and had higher levels of inflammatory markers. Non-White persons had higher antibody concentrations than those who identified as White; these concentrations did not decline during follow-up. Serologic assay results correlated with disease outcome, race, and other risk factors for severe SARS-CoV-2 infection. Serologic assays can be used in surveillance to clarify the duration and protective nature of humoral responses to SARS-CoV-2 infection.


Subject(s)
COVID-19/blood , COVID-19/immunology , Immunoglobulin G/blood , SARS-CoV-2 , Seroconversion , Adult , Aged , Antibodies, Viral/blood , COVID-19/physiopathology , Enzyme-Linked Immunosorbent Assay , Female , Humans , Male , Middle Aged , Reverse Transcriptase Polymerase Chain Reaction
7.
Emerg Infect Dis ; 26(11): 2770-2771, 2020 11.
Article in English | MEDLINE | ID: covidwho-760833

ABSTRACT

PCR of upper respiratory specimens is the diagnostic standard for severe acute respiratory syndrome coronavirus 2 infection. However, saliva sampling is an easy alternative to nasal and throat swabbing. We found similar viral loads in saliva samples and in nasal and throat swab samples from 110 patients with coronavirus disease.


Subject(s)
Betacoronavirus/isolation & purification , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Saliva/virology , Adult , Aged , COVID-19 , COVID-19 Testing , Female , Humans , Male , Middle Aged , Nose/virology , Pandemics , Pharynx/virology , SARS-CoV-2 , Viral Load